Modify

Opened 7 years ago

Last modified 7 years ago

#710 new defect

Can't stop / cleanup simulations that run without a queueing system

Reported by: Erik Schnetter Owned by: Erik Schnetter
Priority: major Milestone:
Component: SimFactory Version:
Keywords: Cc:

Description

For example, simulations running on workstations are affected.

Attachments (0)

Change History (2)

comment:1 Changed 7 years ago by Barry Wardell

I think this is supposed to work, but it doesn't work for me either. I looked into it before and I think the problem seemed to be that the PID recorded by SimFactory is that of the submit script rather than that of the run script. I wasn't able to find a straightforward way to fix this at the time.

comment:2 Changed 7 years ago by Erik Schnetter

All the run scripts that don't use a queuing system are very similar, and very simplistic. One way of correcting this is to implement a "pseudo-qsub" in a script (stored with Simfactory) that we call, and which prints the pid to the screen, so that the mdb entry filtering out the job id (pid) would also need to be updated.

Modify Ticket

Change Properties
Set your email in Preferences
Action
as new The owner will remain Erik Schnetter.
Next status will be 'review'.
as The resolution will be set.
to The owner will be changed from Erik Schnetter to the specified user.
Next status will be 'confirmed'.
The owner will be changed from Erik Schnetter to anonymous.